Description: OMAS board: Error with the media advance sensor controller board
Causes: OMAS disconneceted. OMAS Controller Card damaged.
Remedy: Call agent: • Check that the printer has the latest firmware version. If not, update the firmware to the latest version. Service engineer: 1. Check that OMAS sensor is connected to OMAS Controller Card. 2. Replace the OMAS Controller Card.
Code: 50.3:11
Description: Main PCA to OMAS Controller cable does not seem to be connected
Causes: The cable from Main PCA to OMAS controller has a problem.
Remedy: Service engineer: • Restart the printer. Service engineer: 1. Check that the Main PCA to OMAS Controller cable is not damaged. 2. Check that the Main PCA to OMAS Controller cable is correctly connected to the Main PCA and the OMAS Controller Card.
Code: 50.4:11
Description: OMAS Controller to PrintMech PCA cable does not seem to be connected
Causes: OMAS Controller to PrintMech PCA cable does not seem to be connected.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the OMAS Controller to PrintMech PCA cable is not damaged. 2. Check that the OMAS Controller to PrintMech PCA cable is correctly connected to the PrintMech PCA and the OMAS Controller Card.
Code: 50.5:11
Description: OMAS board: SENSOR_NOT_CONNECTED
Causes: OMAS sensor not connected.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that OMAS sensor is well connected. 2. Replace OMAS sensor. . 3. Replace OMAS controller PCA. See OMAS controller PCA.
Code: 50.6:11
Description: OMAS board: Media sensor board Power cable
Causes: OMAS Controller to Engine PCA cable does not seem to be connected. Power not connected. Problems with 5V line.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the OMAS Controller to Engine PCA cable is not damaged. 2. Check that the OMAS Controller to Engine PCA cable is correctly connected to the Engine PCA and the OMAS Controller Card.
Code: 50:01
Description: OMAS Module communication failure
Causes: OMAS communication failure.
Remedy: Call agent: • Check that the printer has the latest firmware version. If not, update the firmware to the latest version. Service engineer: 1. Check that the OMAS Controller to OMAS Sensor cable is not damaged and is correctly connected to the OMAS Controller Card and the OMAS Module. 2. Replace the OMAS Module. See OMAS.
Code: 50:03
Description: OMAS Controller to PSU cable does not seem to be connected
Causes: The OMAS controller power cable does not seem to be connected.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the PSU to OMAS Controller cable is not damaged. 2. Check that the PSU to OMAS Controller cable is correctly connected to the PSU and the OMAS Controller Card.
Code: 50:11
Description: OMAS: Navigation problems, may be due to a mispositionned sensor, DOF, or skew issue
Causes: OMAS sensor mispositionned.
Remedy: Call agent: • Restart the printer. Service engineer: • Check that the OMAS sensor is well positioned.