Remedy: 1. Check the connection between RX motor and the Connect A PCB (P90). (See page 2-1.) 2. Verify the RX motor rotates when the power is on. If OK, see step 6. 3. Check the power is supplied to the Rx motor. If it does not, see step 5. 4. Replace the RX motor if it doesn’t rotate. 5. Replace the Connect A PCB. 6. If the problem is not correct, replace the main control board.
Code: 02
Description: Fan Error
Remedy: 1. Verify the inside fan rotates when the power is on. 2. Check the connection between the fan and Connect A PCB(P87), Connect A PCB (P80C) and the main board. 3. Replace the fan motor if it doesn’t rotate. 4. Replace the Connect A PCB. 5. Replace the main control board.
Code: 03
Description: Fuser Error
Remedy: 1. Turn on the power again, and verify the fuser warms up. If it does not, see step 4. 2. Check the contact between Fusing thermistor and Connect A PCB(P89). 3. Check the contact between Connect A PCB (P80C) and the main board. 4. Replace the Fuser. 5. After replacing the Fuser, verify the fuser warms up when the power is on. 6. Replace the main control PCB.
Code: 04
Description: Drum Error
Remedy: 1. Verify the drum cartridge is set correctly. 2. Check the point of contacts between drum cartridge and Connect A PCB (P86)D 3. Check the contact between Connect A PCB (P80C) and the main board. 4. Replace the drum cartridge. 5. Replace the Connect A PCB. 6. Replace the main control PCB.
Code: 05
Description: Developer Error
Remedy: 1. Verify the toner cartridge is set correctly. 2. Check the point of contacts between toner cartridge and Connect A PCB (P86). 3. Check the contact between Connect A PCB (P80C) and the main board. 4. Replace the toner cartridge. 5. Replace the Connect A PCB. 6. Replace the main control PCB.
Code: 06
Description: LCD Failure
Remedy: 1. Verify that the power cord is correctly connected and the power switch is ON. 2. Check for a blown fuse or open circuit on the unit’s internal power supply. 3. Check the DC output voltages from the power supply unit to connector P3 on the main control PCB. If any of the following voltages are incorrect, replace the power supply. • Pin 4, 5 : +5 V • Pin 8, 9 : +3.3 V • Pin 6, 7, 10, 11, 14, 15 : GND 4. Check the following connectors: • LCD assembly to the Panel PCB (P52) • Panel PCB (P50) to the Harness to the main control PCB (P5) 5. Replace the associated PCBs and connector harness.
Code: 07
Description: General Power Failure
Remedy: 1. Verify that the power cord is correctly connected and the power switch is ON. 2. Verify that the electrical outlet is on. 3. Check for a blown fuse or open circuit on the unit’s internal power supply. 3. Check the DC output voltages from the power supply unit to connector P3 on the main control PCB. If any of the following voltages are incorrect, replace the power supply. • Pin 4, 5 : +5 V • Pin 8, 9 : +3.3 V • Pin 6, 7, 10, 11, 14, 15 : GND • Pin 12, 13 : +24 V@Pin 1:5 V • Pin 12, 13 : +17 V@Pin 1:0 V
Code: D.0.2
Description: The remote unit is busy. Try the call again.