Mã lỗi Konica-Minolta bizhub 20 — Trang 4/12
Code:
6A
Description: Fuser temperature does not reach 60°C within the specified time (center thermistor)
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
6B
Description: Fuser temperature does not reach 100°C within the specified time (center thermistor)
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
6C
Description: Fuser temperature exceeds its higher limit (center thermistor)
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
6D
Description: Fuser temperature exceeds its lower limit (center thermistor)
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
6E
Description: Fuser temperature does not rise (center thermistor)
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
6F
Description: Hardware detects extremely high temperature of the center or side thermistors
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
70
Description: Fuser motor error
Causes: Motor failure. Main PCB failure
Remedy: Replace the main motor. Replace the main PCB ASSY.
Code:
71
Description: Laser unit polygon motor failure
Causes: Laser unit failure. Main PCB failure
Remedy: Replace the laser unit. Replace the main PCB ASSY.