Code :
- Code: 6A
- Description: Fuser temperature does not reach 60°C within the specified time (center thermistor)
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 6B
- Description: Fuser temperature does not reach 100°C within the specified time (center thermistor)
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 6C
- Description: Fuser temperature exceeds its higher limit (center thermistor)
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 6D
- Description: Fuser temperature exceeds its lower limit (center thermistor)
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 6E
- Description: Fuser temperature does not rise (center thermistor)
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 6F
- Description: Hardware detects extremely high temperature of the center or side thermistors
- Causes: Fuser unit failure. Main PCB failure
- Remedy: Replace the fuser unit. Replace the main PCB ASSY.
- Code: 70
- Description: Fuser motor error
- Causes: Motor failure. Main PCB failure
- Remedy: Replace the main motor. Replace the main PCB ASSY.
- Code: 71
- Description: Laser unit polygon motor failure
- Causes: Laser unit failure. Main PCB failure
- Remedy: Replace the laser unit. Replace the main PCB ASSY.