Causes: Dirt on edge sensor. Harness connection failure of high voltage power supply PCB ASSY. Paper feeding kit worn out (MP/ Tray 1/ Tray 2). Registration front sensor failure. Main PCB failure
Remedy: Clean the edge sensor. Check the harness connection of the high voltage power supply PCB ASSY in the appropriate tray, and reconnect it. Replace the paper feeding kit of the appropriate tray. Procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the high voltage power supply PCB ASSY. Replace the main PCB ASSY.
Remedy: Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the relay rear PCB ASSY. Replace the main PCB ASSY.
Causes: Dirt on PE sensor. Harness connection failure of PE EG sensor PCB ASSY. PE actuator catching on some position. PE sensor failure. HVPS PCB unit failure. Main PCB failure
Remedy: Clean the PE sensor. Check the harness connection of the PE EG sensor PCB ASSY and reconnect it. Correct catching of the PE actuator. Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the PE PG sensor PCB ASSY. Replace the HVPS PCB unit. Replace the main PCB ASSY.
Causes: Harness connection failure of front cover sensor ASSY. Part pressing the front cover sensor ASSY is broken, which is provided at the left side of the front cover inside. Front cover sensor failure. Relay front PCB failure. Main PCB failure
Remedy: Check the harness connection of the front cover sensor ASSY and reconnect it. Replace the front door main or front door unit ASSY. Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the front cover sensor ASSY. Replace the relay front PCB ASSY. Replace the main PCB ASSY.
Causes: ADF cover open sensor arm catching on some position. ADF cover is changed in shape or cracked. ADF cover open sensor failure. ADF relay PCB failure. Main PCB failure
Remedy: Correct catching of the ADF cover open sensor. Replace the ADF cover. Replace the ADF cover open sensor. Replace the ADF relay PCB ASSY. Replace the main PCB ASSY.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.