Mã lỗi Konica-Minolta bizhub 20 — Trang 11/12
Code:
DE
Description: Central temperature of heat roller detected the temperature that was lower than 60°C)
Causes: Relay rear PCB ASSY connection failure. Fuser unit failure. Main PCB failure
Remedy: Reconnect the relay rear PCB ASSY connector correctly. Replace the fuser unit. Replace the main PCB ASSY.
Code:
E0
Description: Program error
Causes: Program failure. Main PCB failure
Remedy: Reinstall the latest firmware. Replace the main PCB ASSY.
Code:
E1
Description: Main PCB failure
Causes: Main PCB failure.
Remedy: Replace the main PCB ASSY.
Code:
E2
Description: Central temperature of heat roller exceeds 280°C
Causes: Fuser unit failure. Main PCB failure
Remedy: Replace the fuser unit. Replace the main PCB ASSY.
Code:
E6
Description: EEPROM error
Causes: Main PCB failure
Remedy: Replace the main PCB ASSY.
Code:
EB
Description: The data reading error for E2PROM
Causes: Main PCB failure
Remedy: Replace the main PCB ASSY.
Code:
EC
Description: Fuser fan failure
Causes: Main fan failure. Main PCB failure
Remedy: Replace the main fan ASSY. Replace the main PCB ASSY.
Code:
EF
Description: LVPS PCB failure
Causes: LVPS PCB failure. Main PCB failure
Remedy: Replace the LVPS PCB ASSY. Replace the main PCB ASSY.