Code :
- Code: B1
- Description: Dark level offset data level error for scanning
- Causes: CCD unit failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY.
- Code: B2
- Description: Gain control data level error for scanning
- Causes: CCD unit failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY
- Code: B7
- Description: A/D converter standard voltage failure; at High side
- Causes: CCD unit failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY
- Code: B8
- Description: A/D converter standard voltage failure; at Low side
- Causes: CCD unit failure. Main PCB failure
- Remedy: .Replace the CCD module. Replace the main PCB ASSY
- Code: B9
- Description: Scanning light adjustment error is detected
- Causes: Scanner module failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY.
- Code: BB
- Description: White level data error
- Causes: Scanner module failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY.
- Code: BD
- Description: Black level data error
- Causes: Scanner module failure. Main PCB failure
- Remedy: Replace the CCD module. Replace the main PCB ASSY.
- Code: BF
- Description: ADF duplex scanning cannot be implemented due to too long document
- Causes: Document front actuator 2 not operating smoothly or catching in some position. Document front sensor 2 failure
- Remedy: Correct smooth operation and that there is no catching of the document front actuator 2. Replace the document front sensor 2.