Description: Failure of discharge detection (Printing becomes unable until the drum is replaced with a new one.) (Discharge detection becomes unable until the drum counter reaches the double of the drum life.)
Causes: Harness connection failure of relay rear PCB ASSY. Eject actuator catching on some position. Paper eject sensor PCB failure. Main PCB failure
Remedy: Check the harness connection of the relay rear PCB ASSY and reconnect it. Correct catching of the eject actuator. Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the relay rear PCB ASSY.
Remedy: Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the Tray 1 PE/edge sensor PCB failure/Tray 2 PE/edge sensor PCB. Check the harness connection of the Tray 1 PE/edge sensor PCB/Tray 2 PE/edge sensor PCB. and reconnect it. Replace the main PCB ASSY. Replace the connector 55533-1219.
Remedy: Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the Tray 1 PE/edge sensor PCB failure/Tray 2 PE/edge sensor PCB. Check the harness connection of the Tray 1 PE/edge sensor PCB/Tray 2 PE/edge sensor PCB. and reconnect it. Replace the main PCB ASSY. Replace the connector 55533-1219.
Causes: Harness connection failure of high voltage power supply PCB ASSY. Registration rear actuator catching on some position. Registration rear sensor failure. Main PCB failure
Remedy: Check the harness connection of the high voltage power supply PCB ASSY and reconnect it. Correct catching of the registration rear actuator. Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the high voltage power supply PCB ASSY. Replace the main PCB ASSY.
Description: Incorrect paper size in duplex printing
Causes: Registration rear sensor failure. Main PCB failure
Remedy: Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the high voltage power supply PCB ASSY. Replace the main PCB ASSY.
Causes: Dirt on edge sensor. Harness connection failure of high voltage power supply PCB ASSY. Paper feeding kit worn out (MP/ Tray 1/ Tray 2). Registration front sensor failure. Main PCB failure
Remedy: Clean the edge sensor. Check the harness connection of the high voltage power supply PCB ASSY in the appropriate tray, and reconnect it. Replace the paper feeding kit of the appropriate tray. Procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the high voltage power supply PCB ASSY. Replace the main PCB ASSY.
Causes: Dirt on edge sensor. Harness connection failure of high voltage power supply PCB ASSY. Paper feeding kit worn out (MP/ Tray 1/ Tray 2). Registration front sensor failure. Main PCB failure
Remedy: Clean the edge sensor. Check the harness connection of the high voltage power supply PCB ASSY in the appropriate tray, and reconnect it. Replace the paper feeding kit of the appropriate tray. Procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the high voltage power supply PCB ASSY. Replace the main PCB ASSY.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.