Description: TCR sensor adjustment failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall developing unit 2 Reinstall toner bottle 3 Check the contact of developing unit for proper connection and correct as necessary. 4 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 5 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 6 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 7 M3 operation check 8 M8 operation check 9 Change developing unit 10 Change TCRSB 11 Change PRCB
Description: TCR sensor failure
Alarm signals for a TCR sensor are detected. This detection is used for detecting disconnection of TCR sensor board (TCRSB) connector.
Remedy: 1 Reinstall developing unit 2 Reinstall toner bottle 3 Check the contact of developing unit for proper connection and correct as necessary. 4 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 5 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 6 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 7 M3 operation check 8 M8 operation check 9 Change developing unit 10 Change TCRSB 11 Change PRCB
Description: Marketing area error
• Marketing area error is detected when reading the backup media of the machine is finished. • Hardware signal is not fixed when the Boot started.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 Change PRCB
Description: FNS communication error (FS-529)
When the FS control board (FSCB) is receiving data, a communication error is detected.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 JSCB F1 conduction check 4 JSCB F2 conduction check 5 Change FSCB
Description: FPGA configuration error
When a configuration check is performed on the extended IC chip (FPGA) located on the printer control board (PRCB), error is detected.
Remedy: 1 Reboot the machine. 2 Rewrite the firmware. 3 Change PRCB
Description: Main backup media access error
• When an error is detected at the data reading process. • The machine writes and reads data, and judges that the data has error. Then the machine performs the same process and judges again that the data has error. • When counter values are read, error is detected. • The machine detects that it does not have EEPROM.
Remedy: 1 Reboot the machine. 2 Check the EEPROM on the PRCB for proper connection and correct as necessary. 3 Change PRCB 4 Change EEPROM
Description: FS NVRAM memory error (FS-529)
When the power switch is turned ON, malfunctioning of the non-volatile memory on the FS control board (FSCB) is detected.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 Change FSCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.