Description: TCR sensor adjustment failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall developing unit 2 Reinstall toner bottle 3 Check the contact of developing unit for proper connection and correct as necessary. 4 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 5 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 6 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 7 M3 operation check 8 M8 operation check 9 Change developing unit 10 Change TCRSB 11 Change PRCB
Code: 0F43
Description: TCR sensor failure
Alarm signals for a TCR sensor are detected. This detection is used for detecting disconnection of TCR sensor board (TCRSB) connector.
Remedy: 1 Reinstall developing unit 2 Reinstall toner bottle 3 Check the contact of developing unit for proper connection and correct as necessary. 4 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 5 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 6 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 7 M3 operation check 8 M8 operation check 9 Change developing unit 10 Change TCRSB 11 Change PRCB
Code: 10A5
Description: Marketing area error
• Marketing area error is detected when reading the backup media of the machine is finished. • Hardware signal is not fixed when the Boot started.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 Change PRCB
Code: 133B
Description: FNS communication error (FS-529)
When the FS control board (FSCB) is receiving data, a communication error is detected.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 JSCB F1 conduction check 4 JSCB F2 conduction check 5 Change FSCB
Code: 1340
Description: FPGA configuration error
When a configuration check is performed on the extended IC chip (FPGA) located on the printer control board (PRCB), error is detected.
Remedy: 1 Reboot the machine. 2 Rewrite the firmware. 3 Change PRCB
Code: 13D0
Description: Main backup media access error
• When an error is detected at the data reading process. • The machine writes and reads data, and judges that the data has error. Then the machine performs the same process and judges again that the data has error. • When counter values are read, error is detected. • The machine detects that it does not have EEPROM.
Remedy: 1 Reboot the machine. 2 Check the EEPROM on the PRCB for proper connection and correct as necessary. 3 Change PRCB 4 Change EEPROM
Code: 13F0
Description: Engine control malfunction
Engine control malfunction is detected with port monitor control.
Remedy: 1 Check the connectors on the PRCB for proper connection and correct or change as necessary. 2 Rewrite the firmware. 3 Change PRCBEPR
Code: 1402
Description: FS NVRAM memory error (FS-529)
When the power switch is turned ON, malfunctioning of the non-volatile memory on the FS control board (FSCB) is detected.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the power switch, wait for 10 sec. or more, and turn ON the power switch. 2 Rewrite the firmware. 3 Change FSCB