Description: Polygon motor rotation trouble
• The polygon motor (M9) fails to turn stably even after the lapse of a given period of time after activating the polygon motor. • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor (M9) is rotating.
Remedy: 1 Check the connector between PH unit-PRCB CN19, CN20 for proper connection and correct as necessary. 2 Change PH unit 3 Change PRCB
Description: Laser malfunction
• SOS signal is not detected even after the lapse of a given period of time after starting the laser output. • SOS signal is not detected for a given period of time during printing.
Remedy: 1 Check the connector between PH unit-PRCB CN19, CN20 for proper connection and correct as necessary. 2 Change PH unit 3 Change PRCB
Description: Fusing heaters trouble (center)
• Detected temperature of the heating roller thermistor (TH2; center) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Description: Fusing heaters trouble (edge)
• Detected temperature of the heating roller thermistor (TH2; edge) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Description: Fusing abnormally low temperature detection (center)
Detected temperature of the heating roller thermistor (TH2; center) goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Description: Fusing abnormally low temperature detection (edge)
Detected temperature of the heating roller thermistor (TH2; edge) goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Description: Fusing abnormally high temperature detection (center)
Detected temperature of the heating roller thermistor (TH2; center) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Description: Fusing abnormally high temperature detection (edge)
Detected temperature of the heating roller thermistor (TH2; edge) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.