Description: 2nd Image Transfer Roller Separation
• The 2nd Image Transfer Pressure Position Sensor doesn’t turn ON (Retracting) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is retracting. • The 2nd Image Transfer Pressure Position Sensor doesn’t turn OFF (Pressuring) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is pressuring.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Change the Right Door Assy. 3 Change PWB-M.
Description: Transfer Belt Separation
• The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting. • The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring.
Description: Color PC Drum Motor's failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the connector of motor for proper drive coupling and correct as necessary. 3 Check the PWB-M connector for proper connection and correct as necessary. 4 M2 operation check (C0018) PWB-M CNDM3-5 (REM) PWB-M CNDM3-8 (LOCK) C-21. 5 Change PWB-M.
Description: Color PC Drum Motor's turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary.
Description: Color Developing Motor's failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the connector of motor for proper drive coupling and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 Check the PWB-M connector for proper connection and correct as necessary. 5 M3 operation check PWB-M CNDM2-5 (REM) PWB-M CNDM2-8 (LOCK) C-20 to 21. 6 Change PU1. 7 Change PWB-M.
Description: Color Developing Motor's turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary.
Description: Transfer Cleaner Unit New Article Release
• A new installation is not detected when a new Transfer Cleaner Unit (Image Transfer Belt Unit) is installed.
Description: Abnormally low toner density detected Cyan TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-20 C-21. 4 Reinstall Imaging Unit. 5 Change Imaging Unit. 6 Change PWB-M. 7 Change PWB-MFP.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.