Description: • A paper exit or paper finishing process inside the finisher is not completed. • The finisher does not start during a reset procedure from the jam.
Causes:
Remedy: 1 Initial check items 2 Open and close the front door of the main body. Or, open and close the front door of the finisher.
Code: C0002
Description: Paper feed communication error. When the MFP board (MFPB) is receiving data, a communication error is detected.
Causes: • MFP board (MFPB) • PC control board (PCCB)
Remedy: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Correct or replace the harness connection between the main body and the paper feed cabinet if faulty. 3. Rewrite the firmware. 4. Replace PCCB. (PC-110/PC-210/PC-410) 5. Replace MFPB.
Code: C0106
Description: Tray 3/LCC paper feed motor turning at abnormal timing (When PC-110, PC-210 or PC-410 is installed) • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: <When PC-110 or PC-210 is installed> • Tray 3 paper feed motor (M111) • PC control board (PCCB) <When PC-410 is installed> • Paper feed motor (M131) • PC control board (PCCB)
Remedy: When PC-110 or PC-210 is installed 1. Check the connector between M111-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M111 for proper drive coupling and correct as necessary. 3. M111 operation check • Control signal: PCCB CN5-5 (CW/CCW) • Location of electrical component: PC-110/PC-210 4-C 4. Replace M111. 5. Replace PCCB. When PC-410 is installed 1. Check the connector between M131-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M131 for proper drive coupling and correct as necessary. 3. M131 operation check • Control signal: PCCB CN5-5 (CW/CCW) • Location of electrical component: PC-410 4-J 4. Replace M131. 5. Replace PCCB.
Code: C0107
Description: Tray 3/LCC vertical transport motor turning at abnormal timing (When PC-110, PC-210 or PC-410 is installed) • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: <When PC-110 or PC-210 is installed> • Tray 3 vertical transport motor (M112) • PC control board (PCCB) <When PC-410 is installed> • Vertical transport motor (M132) • PC control board (PCCB)
Remedy: When PC-110 or PC-210 is installed 1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M112 for proper drive coupling and correct as necessary. 3. M112 operation check • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-110/PC-210 3 to 4-C 4. Replace M112. 5. Replace PCCB. When PC-410 is installed 1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M132 for proper drive coupling and correct as necessary. 3. M132 operation check • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-410 4-J 4. Replace M132. 5. Replace PCCB.
Code: C0108
Description: Tray 4 paper feed motor turning at abnormal timing (When PC-210 is installed) • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Tray 4 paper feed motor (M121) • PC control board (PCCB)
Remedy: 1. Check the connector between M121-PCCB CN9 for proper connection and correct as necessary. 2. Check the connector of M121 for proper drive coupling and correct as necessary. 3. M121 operation check 1. Control signal: PCCB CN9-5 (CW/CCW) 2. Location of electrical component: PC-210 6-K 4. Replace M121. 5. Replace PCCB.
Code: C0109
Description: Tray 4 vertical transport motor turning at abnormal timing (When PC-210 is installed) • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Tray 4 vertical transport motor (M122) • PC control board (PCCB)
Remedy: 1. Check the connector between M122-PCCB CN9 for proper connection and correct as necessary. 2. Check the connector of M122 for proper drive coupling and correct as necessary. 3. M122 operation check • Control signal: PCCB CN9-13 (CW/CCW) • Location of electrical component: PC-210 6-K 4. Replace M122. 5. Replace PCCB.
Code: C0202
Description: Tray 1 feeder up/down abnormality. The tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M12-MFPB CN19E for proper connection and correct as necessary. 3. Check the connector of M12 for proper drive coupling and correct as necessary. 4. Check the connector between PS25-relay CN30-MFPB CN26E for proper connection and correct as necessary. 5. PS25 I/O check, sensor check • Control signal: MFPB CN26E-3 (ON) • Location of electrical component: 25-C 6. M12 operation check • Control signal: MFPB CN19E-5 (REM) • Location of electrical component: 21-C 7. Replace M12. 8. Replace MFPB.
Code: C0204
Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M13-MFPB CN25E for proper connection and correct as necessary. 3. Check the connector of M13 for proper drive coupling and correct as necessary. 4. Check the connector between PS22-relay CN40-MFPB CN23E for proper connection and correct as necessary. 5. PS22 I/O check, sensor check • Control signal: MFPB CN23E-9 (ON) • Location of electrical component: 27-C 6. M13 operation check • Control signal: MFPB CN25E-5 (REM) • Location of electrical component: 22-C 7. Replace M13. 8. Replace MFPB.