Các lỗi thường gặp

Code :
  • Code: 0094
  • Display: XFER DETACH 2
  • Description: 2nd image transfer pressure / retraction failure
    • The retraction position sensor /2 is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started.
    • The retraction position sensor /2 is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check. 7 CL5 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL5. 11 Change MFPB.
  • Code: 0096
  • Display: XFER DETACH 1
  • Description: 1st image transfer pressure / retraction failure
    • The retraction position sensor /1 is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating.
    • The retraction position sensor /1 is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check. 7 CL4 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL4. 11 Change MFPB.
  • Code: 0300
  • Display: POLYGON MOTOR
  • Description: Polygon motor malfunction
    • The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started.
    • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
  • Code: 0310
  • Display: LASER ERROR
  • Description: Laser malfunction
    • The SOS signal is not detected within a given period of time after the output of the laser has been started.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
  • Code: 0500
  • Display: FUSER ERROR
  • Description: Heating roller warm-up failure
    • The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
  • Code: 0501
  • Display: FUSER ERROR
  • Description: Fusing pressure roller warm-up failure
    • The thermistor /2 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
  • Code: 0510
  • Display: FUSER ERROR
  • Description: Abnormally low heating roller temperature
    • The temperature detected by the thermistor /1 remains lower than the specified value for a given period of time or longer.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
  • Code: 0511
  • Display: FUSER ERROR
  • Description: Abnormally low fusing pressure roller temperature
    • The temperature detected by the thermistor /2 remains lower than the specified value for a given period of time or longer.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.