Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (pressed position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's pressing motion.
Remedy: 1 Check the M13 connector for proper connection and correct as necessary. 2 PC29 I/O check PWB-MC PJ24MC-9 (ON) C to D-3. 3 M13 operation check PWB-MC PJ13MC-1 (REM) C to D-2. 4 Change PWB-MC.
Code: C2152
Description: Image Transfer Belt pressure/ retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 5 sec. after the 1st Image Transfer Pressure/ Retraction Motor has started turning during a sequence of the Transfer Belt's retracting motion. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1 sec. after the 1st Image Transfer Pressure/ Retraction Motor has started turning during a sequence of the Transfer Belt's pressing motion.
Remedy: 1 Check the M11 connector for proper connection and correct as necessary. 2 PC12 I/O check PWB-MC PJ20MC-6 (ON) C to D-22. 3 M11 operation check PWB-MC PJ7MC-1 to 4 K-7. 4 Change PWB-MCPWB-MC.
Code: C2160
Description: Cyan PC Drum Charge Corona malfunction
• An output is automatically produced from the PC Drum Charge Corona of each color when the malfunction resetting procedure is performed after C2164 (PC Drum Charge Corona malfunction) has been detected. The SCD signal is detected for a continuous 0.5-sec. period at this time.
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.
Code: C2161
Description: Magenta PC Drum Charge Corona malfunction
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.