Description: LCT vertical transport motor malfunction
Remedy:
Code: C0204
Description: Tray 2 elevator failure
• The lift-up sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M101 connector for proper connection and correct as necessary. 2 Check the connector of M101 for proper drive coupling and correct as necessary. 3 PC115 I/O check PWB-Z PJ6Z-3 (ON) T to U-26. 4 M101 operation check PWB-Z PJ4Z-4 to 5 M-24. 5 Change PWB-Z.
Code: C0206
Description: Tray 3 elevator failure
Remedy:
Code: C0208
Description: Tray 4 elevator failure
Remedy:
Code: C0209
Description: LCT elevator motor malfunction (elevator malfunction)
Remedy:
Code: C0210
Description: LCT ascent motion failure
Remedy:
Code: C0211
Description: Manual tray rise descent error
• The bypass lift-up sensor is not blocked even when the tray 2 vertical transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the standby position to the feed position was started. • The bypass lift-up sensor is not unblocked even when the tray 2 vertical transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the feed position to the standby position was started.