Các lỗi thường gặp

Code :
  • Code: C-1505
  • Description: The switchback conveyance has not been completed within a specified period of time after the SC switchback conveyance motor (M12) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC switchback conveyance motor (M12) DIPSW7-6
  • Remedy: 1. Check the SC switchback conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 4-D) 5. Replace M12. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1506
  • Description: The switchback roller release operation has not been completed within a specified period of time after the SC switchback release motor (M13) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC switchback release motor (M13) DIPSW7-6
  • Remedy: 1. Check the SC switchback release section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 6-D) 5. Replace M13. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1507
  • Description: The SC alignment has not been completed within a specified period of time after SC alignment motor (M15) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC alignment motor (M15) DIPSW7-6
  • Remedy: 1. Check the SC alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:5-D) 5. Replace M15. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1508
  • Description: The SC paper bundle conveyance has not been completed within a specified period of time after the SC bundle conveyance motor (M17) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC bundle conveyance motor (M17) DIPSW7-6
  • Remedy: 1. Check the SC bundle conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:5-D) 5. Replace M17. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1509
  • Description: The SC roller release operation has not been completed within a specified period of time after the SC roller release motor (M18) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC roller release motor (M18) DIPSW7-6
  • Remedy: 1. Check the SC roller release section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 6-D) 5. Replace M18. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1510
  • Description: The SC entrance movement operation has not been completed within a specified period of time after the clamp entrance movement motor (M19) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • Clamp entrance movement motor (M19) DIPSW7-6
  • Remedy: 1. Check the clamp entrance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 5-D) 5. Replace M19. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1511
  • Description: The clamp entrance roller release operation has not been completed within a specified period of time after the clamp entrance roller release motor (M20) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • Clamp entrance roller release motor (M20) DIPSW7-6
  • Remedy: 1. Check the clamp entrance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 7-D) 5. Replace M20. 6. Replace PBDB1. 7. Replace PBCB.
  • Code: C-1512
  • Description: The clamp alignment has not been completed within a specified period of time after clamp alignment motor (M21) turns ON.
  • Causes: • PB control board (PBCB) • PB drive board (PBDB) • Clamp alignment motor (M21) DIPSW7-6
  • Remedy: 1. Check the clamp alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 7-D) 5. Replace M21. 6. Replace PBDB1. 7. Replace PBCB.