Description: The clamp section open/ close operation has not been completed within a specified period of time after the clamp motor (M22) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Clamp motor (M22) DIPSW7-6
Remedy: 1. Check the clamp section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 8-D) 5. Replace M22. 6. Replace PBDB1. 7. Replace PBCB.
Description: The clamp rotation operation has not been completed within a specified period of time after the clamp rotation motor (M23) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Clamp rotation motor (M23) DIPSW7-6
Remedy: 1. Check the clamp section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:8-D) 5. Replace M23. 6. Replace PBDB1. 7. Replace PBCB.
Description: The glue tank movement operation has not been completed within a specified period of time after the glue tank movement motor (M31) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Glue tank movement motor (M31) DIPSW7-6
Remedy: 1. Check the glue tank movement section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 8-D) 5. Replace M31. 6. Replace PBDB1. 7. Replace PBCB.
Description: A rotation error detection signal is detected for a specified period of time in succession while the glue apply roller motor (M32) is driving.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Glue apply roller motor (M32) DIPSW7-6
Remedy: 1. Check the glue apply section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:9-D) 5. Replace M32. 6. Replace PBDB1. 7. Replace PBCB.
Description: The count of a specified number of pellets, which is counted by the pellet supply passage sensor (PS37), has not been reached after the pellet supply pipe motor (M33) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Pellet supply pipe motor (M33) DIPSW7-6
Remedy: 1. Check the pellet supply section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 10-D) 5. Replace M33. 6. Replace PBDB1. 7. Replace PBCB.
Description: The operation of the pellet supply arm has not been completed within a specified period of time after the pellet supply arm motor (M34) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Pellet supply arm motor (M34) DIPSW7-6
Remedy: 1. Check the pellet supply section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 10-D) 5. Replace M34. 6. Replace PBDB1. 7. Replace PBCB.
Description: The alignment in the cover paper table up/down section has not been completed within a specified period of time after the cover paper alignment motor (M41) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper alignment motor (M41) DIPSW7-6
Remedy: 1. Check the cover paper alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:12-D) 5. Replace M41. 6. Replace PBDB1. 7. Replace PBCB.
Description: The booklet exit has not been completed within a specified period of time after the booklet exit motor (M42) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Booklet exit motor (M42) DIPSW7-6
Remedy: 1. Check the booklet exit section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 12-D) 5. Replace M42. 6. Replace PBDB1. 7. Replace PBCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.