Description: Exhaust fan /2 (M81: PB-502, FM81: PB-503) drive abnormality. An error detection signal is detected continuously for specified time period while M81 is started or driving. 35-4
Remedy: 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 3-D PB-503: 3-D 3 Replace M81 (PB-502), FM81 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503).
Description: Pellet supply cooling fan motor (M4: PB-502, FM4: PB-503) rotation abnormality. An error detection signal is detected continuously for specified time period while M4 is started or driving. 35-4
Remedy: 1 Check the connector connection and the wiring between PBDB/PBDB1 and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 3 Replace M4 (PB-502), FM4 (PB-503). - 4 Replace PBDB (PB-502), PBDB1 (PB-503).
Description: Stack assist fan /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation.
Causes: Stack assist fan /Fr (FM1: RU-506) RU control board (RUCB: RU-506)
Remedy: 1 Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. RU-506: 3-B 3 Replace FM1. - 4 Replace RUCB
Description: Stack assist fan /Rr (FM2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation.
Causes: Stack assist fan /Rr (FM2: RU-506) RU control board (RUCB: RU-506)
Remedy: 1 Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. RU-506: 3-B 3 Replace FM2. - 4 Replace RUCB
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FNSCB, and repair it if any abnormality. - 3 Reinstalling FS firmware - 4 Replace FNSCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of RUCB, and repair it if any abnormality. - 3 Reinstalling RU firmware - 4 Replace RUCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.