Description: LPH fan /1 (FM3) rotation abnormality. When the print is started, the EM signal of FM3 turns ON.
Causes: LPH fan /1 (FM3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 4 Replace FM3 - 5 Replace PRCB. - 6 Replace ACDB.
Code: C-5335
Description: LPH fan /2 (FM25) rotation abnormality. When the print is started, the EM signal of FM25 turns ON.
Causes: LPH fan /2 (FM25) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM25. - 5 Replace PRCB. - 6 Replace ACDB.
Code: C-5336
Description: LPH fan /3 (FM26) rotation abnormality. When the print is started, the EM signal of FM26 turns ON.
Causes: LPH fan /3 (FM26) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM26. - 5 Replace PRCB. - 6 Replace ACDB.
Code: C-5337
Description: De-curler fan /1 (FM29) rotation abnormality. The EM error detection signal of FM29 is detected twice in succession within a specified period of time after FM29 was turned ON. At this time, the door close is detected.
Causes: de-curler fan /1 (FM29) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 17-O 3 Replace FM29. - 4 Replace ADUDB. -
Code: C-5338
Description: De-curler fan /2 (FM30) rotation abnormality. The EM error detection signal of FM30 is detected twice in succession within a specified period of time after FM30 was turned ON. At this time, the door close is detected.
Causes: De-curler fan /2 (FM30) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 18-O 3 Replace FM30. - 4 Replace ADUDB.
Code: C-5339
Description: Transfer belt cleaning fan (FM27) rotation abnormality. When the print is started, the EM signal of FM27 turns ON.
Causes: Transfer belt cleaning fan (FM27) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. - 3 Replace FM27. - 4 Replace ADUDB.
Code: C-5340
Description: Rotation abnormality of fans equipped in ADU. The EM error signal is detected twice in succession within a specified period of time after ADU cooling fun /2 (FM15), belt cooling fan (FM37) and reverse cooling fan (FM38) was turned ON. At this time, the door close is detected.
Causes: ADU cooling fan /2 (FM15) Belt cooling fan (FM37) Reverse cooling fan (FM38) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 17-O, 20-O, 21-O 3 Replace FM15. - 3 Replace FM37. - 3 Replace FM38. - 4 Replace ADUDB.
Code: C-5341
Description: Collection pipe cooling fan (FM34) rotation abnormality + 24V power abnormality. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB.