Description: Suction cooling fan /3 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Suction cooling fan /3 (FM8) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 3 Replace FM8 and ACDB at a time.
Description: Suction cooling fan /3 (FM8) rotation abnormality 1. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Suction cooling fan /3 (FM8) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM8. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Cooling fan /1 (FM1) rotation abnormality + 24V power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Cooling fan /1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Cooling fan /1 (FM1) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 3 Replace FM1 and ACDB at a time.
Description: Cooling fan /1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Cooling fan /1 (FM1) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM1. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Cooling fan /2 (FM2) rotation abnormality + 24V power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Cooling fan /2 (FM2) power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Cooling fan /2 (FM2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM2 and ACDB at a time.
Description: Cooling fan /2 (FM2) rotation abnormality 1. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Cooling fan /2 (FM2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 4 Replace FM2. - 5 Replace PRCB. - 6 Replace ACDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.