Description: DC power supply /3 cooling fan (FM36) power abnormality. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: DC power supply /3 cooling fan (FM36) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36 and ACDB at a time.
Code: C-5351
Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: DC power supply /3 cooling fan (FM36) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36. - 4 Replace PRCB.
Code: C-5352
Description: DC power supply /3 cooling fan (FM36) rotation abnormality 2. When the print is started, the EM signal of FM36 turns ON.
Causes: DC power supply /3 cooling fan (FM36) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36. - 4 Replace PRCB.
Code: C-6101
Description: Scanner motor (M27) movement time abnormality + 24V power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (24V cut off) of M27 is detected.
Causes: DC power supply /1 (DCPS/1) Scanner drive board (SDB)
Remedy: Check the connector connection and the wiring between SDB and DCPS /1, and repair it if any abnormality. - 2 Replace DCPS /1. - 3 Replace SDB.
Code: C-6102
Description: Scanner motor (M27) power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.
Causes: Scanner motor (M27) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 3 Replace M27 and SDB at a time.
Code: C-6103
Description: Scanner motor (M27) movement time abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected.
Causes: Scanner home sensor (PS51) APS sensor /1 (PS52) Scanner motor (M27) Scanner drive board (SDB)
Remedy: 1 Check the scanner drive section, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 2-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 5 Replace PS51 and PS52. - 6 Replace M27. - 7 Replace SDB.
Code: C-6301
Description: Scanner cooling fan (FM19) rotation abnormality + 24V power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace SDB.
Code: C-6302
Description: Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.
Causes: Scanner cooling fan (FM19) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 3 Replace FM19 and SDB.