Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 920 — Trang 27/32

Code: SC77-26

Description: After start-up of the folding conveyance motor (M20) operation, the M20 does not get to the predetermined speed within a specified period of time. (FS-604 only)
Causes: FS control board (FSCB) Folding transfer motor (M20)

Code: SC77-31

Description: After start-up of the conveyance motor (M101) operation, the M101 does not get to the predetermined speed within a specified period of time.
Causes: TU drive board (TUDB) Conveyance motor (M101)

Code: SC77-32

Description: After the blade motor (M102) starts the home position detection operation, the blade home switch (MS101) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Blade motor (M102) Blade home switch (MS101)

Code: SC77-33

Description: After the stopper motor (M103) starts the home position detection operation, the stopper home sensor (PS103) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Stopper motor (M103) Stopper home sensor (PS103)

Code: SC77-34

Description: After the stopper release motor (M104) starts the home position detection operation, the stopper release home sensor (PS104) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Stopper release motor (M104) Stopper release home sensor (PS104)

Code: SC77-35

Description: After the press motor (M105) starts the home position detection operation, the press home sensor (PS105) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Press motor (M105) Press home sensor (PS105)

Code: SC77-36

Description: After the pusher motor (M107) starts the home position detection operation, the pusher home sensor (PS112) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Pusher motor (M107) Pusher home sensor (PS112)

Code: SC77-37

Description: After the holder motor (M106) starts the home position detection operation, the upper limit sensor (PS110) does not turn ON within a specified period of time.
Causes: TU drive board (TUDB) Holder motor (M106) Upper limit sensor (PS110)