Description: Fusing motor malfunction
• The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated.
Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M4 operation check MFPB PJ19MFPB-3 to 9 J-3. 5 Change M4. 6 Change MFPB.
Code: 0094
Display: XFER DETACH 2
Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check MFPB PJ16MFPB-8 (ON) C-4 7 CL5 operation check MFPB PJ10MFPB-5 (ON) C-6 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3 9 Change M3. 10 Change CL5. 11 Change MFPB.
Code: 0096
Display: XFER DETACH 1
Description: 1st image transfer pressure / retraction failure
• The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check MFPB PJ7MFPB-11 (ON) J-5. 7 CL4 operation check MFPB PJ19MFPB-2 (REM) J-3 to 4. 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 9 Change M3. 10 Change CL4. 11 Change MFPB.
Code: 0300
Display: POLYGON MOTOR
Description: Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
Code: 0310
Display: LASER ERROR
Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
Code: 0500
Display: FUSER ERROR
Description: Heating roller warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
Code: 0502
Display: TERMISTOR1
Description: Thermistor open-circuit failure
• The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
Code: 0503
Display: TERMISTOR2
Description: Thermistor resistance failure
• The difference between the temperature detected by thermistor/1 and that detected by thermistor/2 exceeds a predetermined value.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.