Description: Cyan ATDC Sensor adjustment failure
Cyan ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Description: Magenta ATDC Sensor adjustment failure
Magenta ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Description: Yellow ATDC Sensor adjustment failure
Yellow ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Description: Black ATDC Sensor adjustment failure
Black ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Malfunction code C0F3D is displayed. YES: Change Imaging Unit. 2 The problem is eliminated after the Imaging Unit has been replaced. NO: Check harness. Check connector for connection. Change Master Board
Description: New Transfer Belt Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. After an image stabilization sequence is completed, the fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 2 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of three cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a third time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Description: New Fusing Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Description: New Fusing Web Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Description: New Oil Coating Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.