Description: Exposure Lamp turning ON at abnormal timing
CCD Sensoroutputsare writteninlineRAM at the end of a scan job and the average of these readings exceeds a predetermined value.
Remedy: 1 Exposure Lamp conduction NO: Change Exposure Lamp. 2 Temperature Fuse conduction. NO: Change Temperature Fuse. 3 Flat Cable conduction NO: Check for correct installation or change. 4 The problem has been eliminated through the checks of steps up to 3. NO: Change DC Power Supply 2. 5 Exposure Lamp turns ON and OFF correctly after DC Power Supply 2 has been replaced. NO: Change Image Processing Board.
Description: Heating Roller warm-up failure (Fusing Thermistor 1)
• Fusing Thermistor 1 does not detect a predetermined temperature and the warm-up cycle is not completed within the period of 9 min. 10 sec. after the warm-up cycle has been started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 30 sec. after the warm-up cycle has started.
Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Heating Roller Heater Lamps turn ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
Description: Lower Fusing Roller Heater Lamp warm-up failure (Fusing Thermistor 2)
•The temperature of Fusing Thermistor 2 does not reach 100 C within 180 sec. after the warm-up cycle has started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 130 sec. after the warm-up cycle has started.
Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
Description: Heating Roller abnormally low temperature (Fusing Thermistor 1)
• The temperature of Fusing Thermistor 1 remains below 120 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 1 remains below 130 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 1 remains below 90 C for 1 sec. or more in the Energy Saver mode.
Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Heating Roller Heater Lamps turn ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
Description: Lower Fusing Roller Heater Lamp abnormally low temperature (Fusing Thermistor 2)
• The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the Energy Saver mode.
Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
Description: Heating Roller abnormally high temperature (Fusing Thermistor 1)
The temperature of Fusing Thermistor 1 remains above 220 C for 1 sec. or more at all times.
Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is 0 Om (or close to 0) with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board..
Description: Lower Fusing Roller Heater Lamp abnormally high temperature (Fusing Thermistor 2)
The temperature of Fusing Thermistor 2 remains above 190 C for 1 sec. or more at all times.
Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is 0 W (or close to 0) with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board.
Description: Scanner Home Sensor malfunction
• The Scanner Home Sensor fails to detect the Scanner at its home position though the Scanner is so located. • The Scanner Home Sensor fails to detect the Scanner though the motor has been energized to move the Scanner over the maximum distance. • The Scanner Home Sensor detects the Scanner at its home position though the Scanner has moved 5 mm away from the home position.
Remedy: 1 Scanner can be moved manually. NO: Correct drive coupling (Scanner Belt tension, pulley operation, drive cable tension) 2 Scan motion: initial scan motion after the Power Switch has been turned ON or Front Door has been opened and closed. NO: Carry out misfeed/malfunction troubleshooting procedures. 3 Connectors are connected properly on Scanner Motor Drive Board: PWB-IC PJ1IC, PJ2IC, and PJ3IC. NO: Check connectors for connection. 4 Scanner Motor turns when the Start key is pressed. NO: Check connectors for connection. Change motor. Change Scanner Motor Drive Board. 5 I/O check for Scanner Home Sensor: the voltage across PJ6C-2 on Image Processing Board and GND is DC 0 V (home position) when the sensor is blocked and DC 5 V when the sensor is unblocked. YES: Change Image Processing Board. NO: Check sensor for installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 6 “IR Area” check: Malfunction when Power Switch is turned ON after “Top Image” has been set to 0 and “FD-Mag.” to 1.000. NO: Adjust “IR Area” data.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.