Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Kyocera KMC2030 — Trang 9/10

Code: C13D1

Description: Cyan IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time.
Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.

Code: C13D2

Description: Magenta IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time.
Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.

Code: C13D3

Description: Yellow IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time.
Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.

Code: C13D4

Description: Black IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time.
Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.

Code: C3310

Description: CCD clamp/gain adjustment failure
• When clamp adjustment is made: (AVE1 -AVE2) =< 4 • When gain adjustment is made: The average of CCD Sensor output values is 1 or less. Dgain = 0 Dgain = 255
Remedy: 1 Check that each of the values displayed on the screen falls within the above range. 2 There is a wide difference between the clamp and gain adjustment values, the value being close to “0” or “255.” YES: Make positive connection of the harness connectors between CCD Sensor Board and Image Processing Board. 3 Clamp adjustment value exceeds the allowable range. YES: Reinstall covers, as extraneous light is the cause of the problem. 4 The lamp adjustment value or gain value exceeds the upper limit of the allowable range, being abnormally great. YES: Clean lens, mirrors, CCD surface, shading sheet, and related parts. 5 The lamp adjustment value or gain value falls short of the lower limit of the allowable range, being abnormally small. YES: Reinstall covers, as extraneous light is the cause of the problem. Change Scanner, as the reflectors are deformed.

Code: C3700

Description: IR Cooling Fan Motor 1 turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started.
Remedy: 1 IR Cooling Fan Motor 1 rotation: the voltage across PJ6C-6 on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor. Master Board

Code: C3710

Description: IR Cooling Fan Motor 2 turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started.
Remedy: 1 IR Cooling Fan Motor 2 rotation: the voltage across PJ6C-9 on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor. Master Board

Code: C3720

Description: Original Glass Cooling Fan Motor turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started.
Remedy: 1 Original Glass Cooling Fan Motor rotation: the voltage across PJ2C-6B on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor.Bo
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie