Description: Lift motor 2 error Lift error that occurs when the lock signal does turn off 510 msec in succession after turning on the cassette lift motor 2 has occurred five times in succession.
Causes: Cassette lift base elevating mechanism. Lift motor 2. Lift sensor 2. Engine PWB
Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift motor 2 and Engine PWB (YC17) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the lift motor 2. Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift sensor 2 and Engine PWB (YC17) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift sensor 2. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.
Code: 1030
Description: PF lift motor 1 error (paper feeder) After cassette 3 is inserted, PF lift sensor 1 does not turn on within 12 s. This error is detected 5 times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after motor is turned on is excluded from detection.
Causes: Cassette lift base elevating mechanism. PF Lift motor 1. PF Lift sensor 1. PF main PWB
Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. PF Lift motor 1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 1 and PF main PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF lift motor 1. PF Lift sensor 1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 1 and PF main PWB 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift sensor 1. PF main PWB Replace the PF main PWB.
Code: 1040
Description: PF lift motor 2 error (paper feeder) After cassette 4 is inserted, PF lift sensor 2 does not turn on within 15 s. This error is detected 5 times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after motor is turned on is excluded from detection.
Causes: Cassette lift base elevating mechanism. PF Lift motor 2. PF Lift sensor 2. PF main PWB
Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 2 and PF main PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF Lift motor2. PF Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 2 and PF main PWB 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift sensor 2. PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
Code: 1100
Description: PF lift motor 1 error (large capacity feeder) After cassette 3 is inserted, PF lift sensor 1 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after PF lift motor 1 is turned on is excluded from detection.
Causes: Paper feeder lift base elevating mechanism. PF Lift motor1. PF Lift sensor1. PF main PWB
Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. PF Lift motor1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 1 and PF main PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF lift motor1. PF Lift sensor1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 1 and PF main PWB 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift sensor1. PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
Code: 1110
Description: PF lift motor 2 error (large capacity feeder) After cassette 4 is inserted, PF lift sensor 2 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after PF lift motor 2 is turned on is excluded from detection.
Causes: Paper feeder lift base elevating mechanism. PF Lift motor 2. PF Lift sensor2. PF main PWB
Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace. PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 2 and PF main PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF Lift motor2. PF Lift sensor2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 2 and PF main PWB 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift sensor 2. PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
Code: 1800
Description: Paper feeder communication error A communication error from paper feeder is detected 10 times in succession.
Causes: Paper feeder. PF main PWB. Engine PWB
Remedy: Paper feeder Check the wiring connection status with the main unit and, if necessary, try connecting it again. PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB and Engine PWB (YC20) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB (Refer to the service manual for the paper feeder). Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.
Code: 1900
Description: Paper feeder EEPROM error When writing the data, read and write data does not match 4 times in succession.
Causes: PF main PWB (EEPROM)
Remedy: PF main PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Code: 2000
Description: Main motor steady-state error After main motor is stabilized, the ready signal is at the H level for 2 s continuously.
Causes: Main motor. Engine PWB
Remedy: Main motor 1. To check the motor operation execute U030 Main (main motor). 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Main motor and Engine PWB (YC13) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the main motor. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.