Description: No fullwave signal. Full wave signal is not detected.
Causes: The PCU PWB connector or the power unit harness is disconnected or broken. PCU PWB trouble Power unit trouble
Remedy: Check connection of the harness and connector. Replace PCU PWB. Replace the power unit.
Code: L8 02
Description: Full wave signal width abnormality. It is judged as frequency abnormality of full wave signal. (When the detection cycle is judged as 69Hz or above or 42.5Hz or below)
Causes: The connector or harness of the PCU PWB and the power PWB is disconnected. PCU PWB trouble Power unit trouble
Remedy: Check connection of the harness and connector. Replace the PCU PWB. Replace the power unit.
Code: PF 00
Description: RIC copy inhibit signal is received. Copy inhibit command from RIM (host) is received.
Causes: Judged by the host.
Remedy: Inform to the host.
Code: U1 01
Description: Backup SRAM battery voltage fall
Causes: Battery life Battery circuit abnormality
Remedy: Check that the battery voltage is about 2.5V or above. Check the battery circuit.
Causes: EEPROM trouble EEPROM is not initialized. Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Code: U2 11
Description: Counter check sum error (Controller). Counter data area check sum error
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Code: U2 12
Description: Adjustment value check sum error (Controller)
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Code: U2 90
Description: PCU EEPROM write error
Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.