Code: 154

Display: Service Call 154: Error
Description: When belt unit fuse cannot be cut.
Remedy: Is the belt unit mounted normally? Yes Check cable connection, then replace engine PCB.

Code: 155

Display: Service Call 155: Error
Description: When fuser unit fuse cannot be cut.
Remedy: Is the fuser unit mounted normally? Yes Check cable connection, then replace engine PCB.

Code: 160 ... 163

Display: Service Call 160: Y Toner 161: M Toner 162: C Toner 163: K Toner
Description: Toner sensor detected error.
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Replace toner sensor or Assy (SGG-PWB). Replace toner sensor or Assy (SGG-PWB).

Code: 167

Display: Service Call 167: Error
Description: Thermistor Slope Error
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Turn ON power again. Leave in that state for 30 minutes then turn ON power again.

Code: 168

Display: Service Call 168: Error
Description: Compensation Thermistor Error
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Turn ON power again. Leave in that state for 30 minutes then turn ON power again.

Code: 169

Display: Service Call 169: Error
Description: Upper Side Thermistor Error
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Turn ON power again. Leave in that state for 30 minutes then turn ON power again.

Code: 170 ... 175

Display: Service Call 170: Error 171: Error 174: Error 175: Error
Description: Fuser Thermistor short-circuit or Open is detected (High Temperature (HOT) or Low Temperature (COLD))
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Turn ON power again. Leave in that state for 30 minutes then turn ON power again.

Code: 172 ... 176

Display: Service Call 172: Error 176: Error
Description: Thermistor indicates High Temperature (HOT) Error.
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again?
Turn ON power again. Leave in that state for 30 minutes then turn ON power again.