Display: Service Call 203: Error 204: Error 207: Error to 214: Error Power Off/on nnn: p 0xFOC: Error 0xFOD: Error 0xFFE: Error 0xFFF: Error
Description: CU Program Dysfunction Detected illegal process with CU program.
Remedy: Detected illegal process with CU program. Yes Write down the 24 digit number displayed on the LCD panel and report it. Turn OFF the power. Then check the insertion of the CU board. Now turn ON the power again.
Code: 209
Display: Power On/off209: DOWNLOAD ERROR
Description: Custom Media Table Download Error Failed to download custom media table.
Remedy: Failed to download custom media table. After turning ON the power again, try downloading again. (This process isn’t executed for regular operations, therefore, will not occur)
Code: 220
Display: Service Call 220: Error
Description: Print Satistic mismatch HDD was removed or replaced after print statistic is set to ON.
Remedy: HDD was removed or replaced after print statistic is set to ON. Get the original HDD back.
Code: 230
Display: Service Call 230: Error
Description: RFID Reader not Installed
Remedy: 1) RFID read device error 2) Does the Error take place again? Check the connection of the RFID R/W board. Replace the RFID R/W board. Replace the S2V board.
Code: 231
Display: Service Call 231: Error
Description: RFID Reader I/F Error An interface error was detected with the RFID reader device. 01: communication error between the RFID reader and the engine PCB. 02: the transceiver circuit error of the RFID reader. 03: communication error between the RFID reader and the Tag chip. 04: the RFID Tag detection error (more than 4 chips).
Remedy: 01: Same action as for error 230 02: Replace the RFID R/W board. 03: Check the connection of the antenna cable. 04: Check to confirm that the number of RFID tags is correct.
Code: 240 ... 248
Display: Service Call 240: Error to 245: Error 247: Error 248: Error
Remedy: Check to confirm that the tray is mounted correctly. Replace the geared motor of the tray.
Code: 917
Display: Power Off/on 917: Error
Description: Belt Slit Sensor Error The belt is not running properly.
Remedy: The belt is not running properly. Does the error message still appear after rebooting? Yes Check to confirm that the belt is mounted correctly. Replace the belt.