Description: Fuser Motor Lock Error The fuser is not operating properly.
Remedy: The fuser is not operating properly. Does the error still occur? Check to confirm that the fuser is in position. Replace the fuser. Replace the fuser motor.
Description: Waste Toner Transfer Motor Lock Error The waste toner transfer motor is not operating properly.
Remedy: The waste toner transfer motor is not operating properly. Does the error still occur? Yes Check to confirm that the waste toner transfer system is operating properly. Replace the waste toner motor.
Remedy: The duplex CPU clock frequency is not correct.Does the error still occur? Yes Check the connection of the V72-2 board. Replace the V72-2 board.
Remedy: The inverter CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-3 board. Replace the V72-3 board.
Remedy: The tray-2 CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-1 board of tray 2. Replace the V72-1 board.