Description: Thermistor indicates Low Temperature (COLD) Error.
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again? Turn ON power again. Leave in that state for 30 minutes then turn ON power again.
Code: 179
Display: Service Call 179: Error
Description: Wrong Fuser Standard
Remedy: 1) Is the model and power voltage of the fuser mounted proper? 2) Fuser is properly mounted, but Error results again. Assemble the proper fuser. Check to see that the fuser is properly assemble. Replace fuser.
Code: 180 ... 186
Display: Service Call 180: Error to 186: Error
Description: The engine detects communication is not possible with the optional unit. 180:Envelope Feeder (Unused) 181:Duplex unit 182:Tray2 unit 183:Tray3 unit 184:Tray4 unit 185:Tray5 unit 186:Finisher unit
Remedy: 1) Is an Error message displayed? 2) Does the Error take place again? Turn ON power again. Replace optional unit.
Code: 187
Display: Service Call 187: Error
Description: Communication with control panel failed.
Remedy: Is the control panel and cable connected properly? Connect properly Replace the control panel and cable.
Code: 188
Display: Service Call 188: Error
Description: Sub-CPU I/F Error
Remedy: Sub-CPU Communication Error. Check the connection of the S2M board. Replace the S2M board.
Code: 189
Display: Service Call 189: Error
Description: Inverter Unit I/F Error
Remedy: 1) Inverter communications error 2) Does the Error take place again? Check the connection of the I/F cable. Replace the V72-3 board.
Code: 190
Display: Service Call 190: Error
Description: System Memory Overflow
Remedy: System Memory Overflow Power OFF/ON Replace CU PCB. (Replace EEPROM)
Code: 200 ... 202
Display: Service Call 200: Error to 202: Error
Description: PU Firm Download Error Error occurred when downloading PU firmware.
Remedy: Error occurred when downloading PU firmware. After turning ON the power again, try downloading again. (This process isn’t executed for regular operations, therefore, will not occur)