Description: Development bias leak
A development bias leak signal is detected.
Causes: • Poor connection of the PCU • High voltage supply board defective
Code: 392
Description: TD sensor initial setting error
TD sensor output voltage falls out of the adjustment range (2.0 +- 0.2 V) after the TD sensor initial setting has been finished.
Causes: • Someone forgot to remove the toner seal of the PCU • ID sensor defective • TD sensor abnormal • Drum does not turn • Development roller does not turn • Poor connection of the PCU
Code: 401
Description: Transfer roller leak error 1
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Code: 402
Description: Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Code: 411
Description: Separation bias leak error
A separation bias leak signal is detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Discharge plate defective
Code: 490
Description: Toner supply motor leak error
Over 1 A supplied to the toner supply motor for longer than 200 ms.
Causes: Toner supply motor defective
Code: 500
Description: Main motor lock
A main motor lock signal is not detected for more than 500 ms after the main motor starts to rotate, or the lock signal is not detected for more than 500 ms during rotation after the last signal.
Causes: • Too much load on the drive mechanism • Main motor defective
Code: 501
Description: 1st paper tray lift motor malfunction
Causes: • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection