Description: Full power error (pressure roller)
Fusing unit warm-up is complete.→ The fusing pressure roller stops turning. → The pressure roller lamp keeps outputting the maximum power for 200 seconds.
Description: Unstable temperature (pressure roller)
The pressure roller thermistor detects unstable temperature increases or decreases within 60 seconds.
Description: Fusing oil overflow
• The oil overflow sensor detects oil. • When the machine covers are closed, the oil supply unit is not detected. • When the machine covers are closed, the fusing unit is not detected.
Causes: • Defective oil end sensor • Defective oil overflow sensor • Defective sensor cable • Oil supply unit not installed