Description: TD sensor error
The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying.
Causes: • TD sensor abnormal • Poor connection of the PCU
Code: 391
Description: Development bias leak
A development bias leak signal is detected.
Causes: • Poor connection of the PCU • High voltage supply board defective
Code: 392
Description: TD sensor initial setting error
TD sensor output voltage falls out of the adjustment range (2.0 ±<> 0.2 V) after the TD sensor initial setting has been finished.
Causes: • Someone forgot to remove the toner seal of the PCU • ID sensor defective • TD sensor abnormal • Drum does not turn • Development roller does not turn • Poor connection of the PCU
Code: 399
Description: Illegal toner bottle (South Korea only)
The toner bottle installed is not intended for use with this machine.
Causes: • Install the correct type of toner bottle.
Code: 401
Description: Transfer roller leak error 1
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Code: 402
Description: Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Code: 411
Description: Separation bias leak error
A separation bias leak signal is detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Discharge plate defective
Code: 490
Description: Toner supply motor leak error
Over 1 A supplied to the toner supply motor for longer than 200 ms