Code: SC302

Description: High voltage power supply error Definition: [B] A charge roller current leak signal is detected.
Causes: · Charge roller damaged · Charge high voltage supply board defective · Poor connection of the PCU

Code: SC320

Description: Polygon mirror motor error Definition: [B] The polygon mirror motor does not reach its operating speed within 10 seconds after the polygon mirror motor on signal, or the lock signal is not detected for more than 200 ms continuously during operation.
Causes: · Polygon mirror motor defective · Poor connection between the polygon mirror motor driver and the engine board · Engine board defective

Code: SC321

Description: No laser writing signal (F-GATE) error Definition: [B] The laser writing signal (F-GATE) is still not LOW when the laser writing area +5 mm has passed since the laser writing start position on the drum.
Causes: · Engine board defective · Printer controller board defective

Code: SC322

Description: Laser synchronization error Definition: [B] The main scan synchronization detector board cannot detect the laser synchronization signal for more than 500 ms.
Causes: · Poor connection between the laser synchronization detector board and the engine board · Laser synchronization detector board out of position · Laser synchronization detector board defective · Engine board defective · LD unit defective

Code: SC324

Description: LD drive current over Definition: [B] The LD drive board applies more than 100 mA to the LD.
Causes: · LD unit defective (not enough power, due to aging) · Poor connection between the LD unit and the engine board · Engine board defective

Code: SC390

Description: TD sensor error Definition: [B] The TD sensor outputs less than 0.5V or more than 4.0V 10 consecutively during printing.
Causes: · TD sensor abnormal · Poor connection of the PCU

Code: SC391

Description: Development bias leak Definition: [B] A development bias leak signal is detected.
Causes: · Poor connection of the PCU · High voltage supply board defective

Code: SC392

Description: TD sensor initial setting error Definition: [B] TD sensor output voltage falls out of the adjustment range after the TD sensor initial setting has been finished.
Causes: · The toner seal of the PCU was not removed · ID sensor defective · TD sensor abnormal · The Drum is not turning · Development roller does not turn · Poor connection of the PCU