Description: 2nd Laser Synchronization Error Definition [B] The 2nd laser synchronization signal cannot be detected by the main scan synchronization detector board even if the laser diodes are activated.
Causes: · Poor connection between the laser synchronization detector board and the LD unit. · Laser synchronization detector board out of position · Laser synchronization detector board defective · LD unit defective
Description: LD Unit Home Position Error 1 Definition [B] The LD unit home position sensor does not detect an on condition when the LD unit moves to its home position.
Causes: · LD unit home position sensor defective · LD positioning motor defective · LD unit movement blocked because of incorrect connector routing
Description: LD Unit Home Position Error 2 Definition [B] The LD unit home position sensor does not detect an off condition when the LD unit moves from its home position.
Causes: · LD unit home position sensor defective · LD positioning motor defective · LD unit movement blocked because of incorrect connector routing
Description: Laser Beam Pitch Adjustment Error Definition [B] The LD unit home position sensor does not detect an on condition while changing the LD unit position for correcting the LD position or changing the dpi.
Causes: · The laser beam pitch adjustment (SP2-6-3 and 4) was not done after replacing the NVRAM or doing an NVRAM clear. · The laser beam pitch adjustment (SP2-6-1 ~ 4) was not done after replacing the LD unit. · LD unit movement blocked because of incorrect connector routing
Description: ID Sensor Error 1 Definition [D] One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsp>=2.5 V 2) Vsg<=2.5 V 3) Vsp = 0 V 4) Vsg = 0 V
Causes: · ID sensor defective · ID sensor connector defective · Poor ID sensor connector connection · I/O board (IOB) defective · High voltage supply board defective · Dirty ID sensor · Defect at ID sensor pattern writing area of the drum
Description: ID Sensor Error 2 Definition [D] The ID sensor output voltage is 5.0 V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern.
Causes: · ID sensor defective · ID sensor connector defective · Poor ID sensor connector connection · I/O board (IOB) defective · High voltage supply board defective · Dirty ID sensor · Defect at the ID sensor pattern writing area of the drum
Description: ID Sensor Error 3 Definition [D] The ID sensor pattern edge voltage is detected to be not 2.5 V twice consecutively during an 800 ms interval.
Causes: · ID sensor defective · ID sensor connector defective · Poor ID sensor connector connection · I/O board (IOB) defective · High voltage supply board defective · Dirty ID sensor · Defect at the ID sensor pattern writing area of the drum
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.