Mã lỗi Ricoh Aficio MP301SP

Code: 101

Description: Exposure Lamp Error
The scanner has scanned the white plate, but cannot detect the white level.
Causes: • Defective exposure lamp
• Defective exposure lamp stabilizer
• Defective exposure lamp connector
• Unclean scanner mirror
• Scanner mirror out of position
• Defective SBU board
• Defective SBU connector
• Lens block out of position
• Incorrect position or width of white plate scanning (* SP4-015)

Code: 120

Description: Scanner home position error 1
The scanner home position sensor does not detect the scanner leaving the home position.
Causes: • Defective scanner home position sensor
• Defective scanner drive motor
• Defective scanner home position sensor connector
• Defective scanner drive motor connector
• Defective BICU board

Code: 121

Description: Scanner home position error 2
The scanner home position sensor does not detect the scanner coming back to the home position.
Causes: • Defective scanner home position sensor
• Defective scanner drive motor
• Defective scanner home position sensor connector
• Defective scanner drive motor connector
• Defective BICU board

Code: 141

Description: SBU black level correction error
• The automatic SBU adjustment has failed to correct the black level three times at the pre-offset adjustment.
• The automatic SBU adjustment has failed to correct the black level ten times at the PGA adjustment.
• The automatic SBU adjustment has failed to correct the black level ten times at the offset adjustment.
Causes: • Defective SBU board

Code: 142

Description: SBU white/black level correction error
The automatic SBU adjustment has failed to correct the white level ten times at the PGA adjustment.
Causes: • Defective exposure lamp
• Unclean white plate
• Incorrect position or width of white plate scanning (* SP4-015)
• Defective SBU board

Code: 144

Description: Communication Error between BICU and SBU
The BICU cannot correctly establish communication with the SBU.
Causes: • Loose connection of the flat cable between the BICU and the SBU
• Defective flat cable between the BICU and the SBU
• Defective BICU
• Defective SBU

Code: 161-001

Description: IPU error: LSYNC error
Detecting an error from the result of the IPU self-check on startup.
Causes: • Defective the IPU or the BICU (or bad connection between the ASIC and the LEO, LSYNC Abnormal, etc)
• Cable bad connection between the SBU and the IPU (or the BICU).

Code: 161-002

Description: IPU error: RI response error
Detecting an error on access to the RI.
Causes: • Defective the IPU (the BICU, the ICTL) or RI abnormal performance, etc