Code: 401

Description: Transfer roller leak error (positive electrode)
• The feedback voltage of the transfer roller has been more than the certain voltage for 200msec. (Open detecting condition)
• The feedback voltage of the transfer roller has been insufficient for 200msec. (Leak detecting condition)
This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective harness connected to HVP
• Defective the MD

Code: 402

Description: Transfer roller leak error (negative electrode)
The feedback voltage of the transfer roller has been more than the certain voltage (more than 4.5V) for 200msec. This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective the MD
• Defective harness connected to the HVP

Code: 411

Description: Separation high-voltage error
The maximum rate of PWM duty (50%) occurs ten times in series (20msec x 10) This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective the MD, HVP Connection harness.

Code: 440

Description: Transfer electric plus current error
Detecting "0" (Abnormal) ten times in series (200ms) while monitoring "HVP: T +: Output error detection signal" every 20m seconds. (Reboot the machine to clear this SC)
Causes:

Code: 460

Description: Isolation voltage error
Detecting "0" (Abnormal) ten times in series (200ms) while monitoring "HVP: D: Output error detection signal" every 20m seconds. (Reboot the machine to clear this SC)
Causes:

Code: 490

Description: Toner bottle motor overcurrent
Detecting "Low" for more than 200msec while the motor on. Motor locked up due to overcurrent to the drive section.
Causes: • Defective the motor drive.

Code: 500

Description: Main motor error
Detecting “High” condition twenty times in series during watching each lock signal after switching motor on.
Causes: • Overload
• Defective main motor drive

Code: 541

Description: Fusing thermistor disconnection
Detecting the temperature remains lower than 0 degrees Celsius for 5 seconds.
Causes: • Thermistor disconnection
• Defective connector part