Các lỗi thường gặp

Code :
  • Code: 557
  • Description: Over zero cross frequency
    The number of times Low-frequency wave detection is less than 1 time.
  • Causes: • Interruption of power source line noise.
  • Code: 559
  • Description: Consecutive fusing jam
    The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
  • Causes: • Paper jam in the fusing unit.
  • Code: 620
  • Description: ADF communication error
    Disconnection after connection in normal.
  • Causes: • Defective the ADF
    • Defective the IPU board
    • Bad connection of the ADF
  • Code: 622
  • Description: Bank communication error
    1. Malfunction occurs on line connection.
    2. Receiving a communication error notice from the URAT.
  • Causes: • Defective the bank control board
    • Defective the BICU, the IOB
    • Bad connection between the bank and the main machine
    • Defective the bank control
  • Code: 623
  • Description: Second bank communication error
    Abnormal code is send from the bank unit.
  • Causes: • Bad connection between the first bank and the second bank
    • Defective the bank control board
    • NOT all connectors are in place
  • Code: 632
  • Description: MF accounting device error 1
    The machine sends a data frame. No normal end signal returns. This symptom happens three times.
  • Causes: • Defective or broken line between machine and device
  • Code: 633
  • Description: MF accounting device error 2
    The machine is communicating with the accounting device. The break signal returns.
  • Causes: Defective or broken line between machine and device
  • Code: 634
  • Description: MF accounting device error 3
    A backup RAM error is reported from the accounting device.
  • Causes: • Defective accounting device controller
    • Defective battery in the accounting device
‹ First  < 3 4 5 6 7 8 9 >  Last ›