Description: Exposure lamp error 1 The standard white level could not be set properly when scanning the white plate during automatic white level adjustment.
Causes: • White plate dirty • Spurious electrical noise on power supply line • Exposure lamp connection loose, broken, defective • Exposure lamp defective • Lamp stabilizer connection, loose, broken, defective • Lamp stabilizer defective • High voltage power supply harness loose, broken, defective • SBU defective • BCU defective • SIO defective
Code: 101-2
Description: Exposure lamp error 1 The standard white level setting dropped below the specified range during scanning.
Causes: • White plate dirty • Spurious electrical noise on power supply line • Exposure lamp connection loose, broken, defective • Exposure lamp defective • Lamp stabilizer connection, loose, broken, defective • Lamp stabilizer defective • High voltage power supply harness loose, broken, defective • SBU defective • BCU defective • SIO defective
Code: 120
Description: Scanner home position error 1 The scanner HP sensor did not turn off during scanner initialization or copying.
Causes: • Scanner motor harness loose, broken, defective at scanner motor or at BCU • Scanner HP sensor harness, loose, broken, defective at HP sensor or at BCU • Scanner motor or motor driver board defective • Scanner motor drive board defective • Scanner HP sensor defective • BCU defective
Code: 121
Description: Scanner home position error 1 The scanner HP sensor did not turn on during scanner initialization or copying.
Causes: • Scanner motor harness loose, broken, defective at scanner motor or at BCU • Scanner HP sensor harness, loose, broken, defective at HP sensor or at BCU • Scanner motor or motor driver board defective • Scanner motor drive board defective • Scanner HP sensor defective • BCU defective
Code: 141
Description: Black level correction error Black level correction could not be set properly during automatic adjustment.
Causes: • Harnesses at the SBU, IPU, BCU loose, broken, defective. • SBU defective • IPU defective • BCU defective
Code: 142
Description: White level correction error White level correction could not be set properly during automatic adjustment.
Causes: • Harnesses at SBU, IPU, BCU loose, broken, defective • Spurious electrical noise on power supply line • White plate dirty or missing • Anti-condensation heater (option) in scanner unit not operating • Exposure lamp harness, loose, broken, defective • Exposure lamp defective • Lamp stabilizer harness loose, broken, defective • Lamp stabilizer defective • SBU defective • IPU defective • BCU defective • SIO Defective
Code: 143
Description: SBU auto adjust error The machine could not acquire the white or black peak level setting at power on.
Causes: • Exposure lamp, lamp stabilizer harness connection loose, broken, defective • Exposure lamp defective • Lamp stabilizer defective • Spurious electrical noise on power supply line • White plate dirty or missing • Anti-condensation heater (option) in scanner unit not operating • Harness connection at SBU, iPU, BCU, SIO, loose, broken, defective • SBU defective • IPU defective • BCU defective • SIO Defective
Code: 144-1
Description: SBU connection error Connection to the SBU could not be confirmed, possibly due to a defect in the BCU detection board
Causes: • Harness connection at IPU, BCU, SBU loose, broken, defective. • Spurious electrical noise on power supply line • IPU defective • BCU defective • SBU defective