Code: 823

Description: Self-diagnostic error: NIB
Causes: [6101] MAC address check sum error The result of the MAC address check sum does not match the check sum stored in ROM. [6104] PHY IC error The PHY IC on the controller cannot be correctly recognized. [6105] PHY IC loop-back error An error occurred during the loop-back test for the PHY IC on the controller. - 1. Replace the controller.
Remedy:

Code: 824

Description: Self-diagnostic error 4: NVRAM
One or more of the following conditions exist: • NVRAM not present. • NVRAM damaged • NVRAM socket damaged
Causes: • NVRAM defective • Controller board defective • NVRAM backup battery exhausted • NVRAM socket damaged Note: In every case, the controller board must be replaced.
Remedy:

Code: 829

Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
Causes: • Replace the optional memory board • Controller board defective
Remedy:

Code: 833

Description: Self-diagnostic error 8: Engine I/F ASIC
Causes: 0F30 0F31 ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. • ASCI (Mandolin) for system control is defective • Interface between North Bridge and AGPI is defective • Replace the mother board 0F41 The read/write check done for resident RAM on the mother board could not be done correctly. • Memory device defective • Replace the mother board 50B1 Could not initialize or read the bus connection. • Bus connection defective, loose • SSCG defective • Replace the mother board 50B2 Value of the SSCG register is incorrect. • Bus connection loose, defective • SSCG defective • Replace the mother board
Remedy:

Code: 834

Description: Self-diagnostic error 9: Optional Memory RAM DIMM
Causes: 5101 The write/verify check for the optional RAM chip on the engine mother board gave an error. • Controller defective • Mother board defective
Remedy:

Code: 838

Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: • Replace the controller board
Remedy:

Code: 851

Description: IEEE 1394 I/F error
Driver setting incorrect and cannot be used by the 1394 I/F.
Causes: • NIB (PHY), LINK module defective; change the Interface Board • Controller board defective
Remedy:

Code: 853

Description: Wireless LAN Error 1
During machine start-up, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802.11b or Bluetooth).
Causes: • Wireless LAN card missing (was removed)
Remedy: