Description: Exposure lamp error The peak white level is less than 64/255 digits (8 bits) when scanning the shading plate.
Causes: • Exposure lamp defective • Lamp stabilizer defective • Exposure lamp connector defective • Standard white plate dirty • Scanner mirror or scanner lens out of position or dirty
Remedy: 1. Check and clean the scanner mirror(s) and scanner lens. 2. Check and clean the shading plate. 3. Replace the exposure lamp. 4. Replace the lamp stabilizer. 5. Replace the scanner mirror(s) or scanner lens.
Code: 120
Description: Scanner home position error 1 The scanner home position sensor does not detect the “OFF” condition during operation.
Causes: • Scanner motor driver defective • Scanner motor defective • Harness between SIO board and scanner motor disconnected • Scanner HP sensor defective • Harness between SIO and HP sensor disconnected
Remedy: 1. Check the cable connection between the BCU and scanner motor. 2. Check the cable connection between the BCU and HP sensor. 3. Replace the scanner motor. 4. Replace the scanner HP sensor.
Code: 121
Description: Scanner home position error 2 The scanner home position sensor does not detect the “ON” condition during operation.
Causes: • Scanner motor driver defective • Scanner motor defective • Harness between SIO board and scanner motor disconnected • Scanner HP sensor defective • Harness between SIO and HP sensor disconnected
Remedy: 1. Check the cable connection between the BCU board and scanner motor. 2. Check the cable connection between the BCU and HP sensor. 3. Replace the scanner motor. 4. Replace the scanner HP sensor.
Code: 141
Description: Black level detection error The black level cannot be adjusted within the target value during the zero clamp.
Causes: • Harness disconnected • Defective SBU
Remedy: 1. Check the cable connection 2. Replace the SBU.
Code: 142
Description: White level detection error The white level cannot be adjusted within the target during auto gain control.
Remedy: 1. Clean the exposure glass, white plate, mirrors, and lens. 2. Check if the exposure lamp is lit during initialization. 3. Check the harness connection between SBU and BCU. 4. Replace the exposure lamp. 5. Replace the scanner motor. 6. Replace the SBU board.
Code: 144
Description: SBU communication error The SBU connection cannot be detected at power on or recovery from the energy save mode.
Causes: • Defective SBU • Defective harness • Defective detection port on the BICU
Remedy: 1. Replace the harness. 2. Replace the SBU. 3. Replace the BCU.
Code: 161-001
Description: The error result of self-diagnostic by the ASIC on the BICU is detected.
Causes: • Defective BICU • Defective connection between BICU and SBU
Remedy: 1. Check the connection between IPU and SBU. 2. Replace the IPU board. 3. Replace the BCU.
Code: 161-002
Description: IPU error Detected an error during an access to the Ri.
Causes: • Defective BICU board
Remedy: 1. Replace the IPU board. 2. Replace the BCU.