Description: Heating roller warm-up error 2 The heating roller temperature does not reach the ready temperature while 70 seconds after the heating lamp on.
Remedy: 1. Check if the heating roller thermistor (end) is firmly connected. 2. Replace the heating roller thermistor (end). 3. Replace the heating roller fusing lamp.
Code: 553
Description: Heating roller fusing lamp overheat 2 (software error) The detected pressure roller temperature stays at 230°C or more for 1 second.
Causes: • Defective PSU • Defective BCU
Remedy: 1. Replace the PSU. 2. Replace the BCU.
Code: 554
Description: Heating roller fusing lamp overheat 2 (hardware error) The heating roller thermistor (end) detects 250°C or more.
Causes: • Defective heating roller thermistor (end) • Defective PSU • Defective BCU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the BCU.
Code: 555
Description: Heating roller lamp consecutive full power 2 When the fusing unit is not running in the ready condition, the pressure roller-fusing lamp keeps ON full power for 8 seconds or more.
Remedy: 1. Replace the heating roller thermostat. 2. Replace the heating roller fusing lamp.
Code: 557
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Causes: • Noise (High frequency)
Remedy: Check the power supply source.
Code: 559
Description: Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Remedy: Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.
Code: 561
Description: Pressure roller thermister error 3 The temperature measured by the pressure roller thermistor (center) does not reach 0 °C for 20 seconds.