Description: Tray 4 error (Paper Feed Unit or LCT) For the two-tray paper feed unit When the tray lift motor is turned on, the upper limit is not detected within 10 seconds. If this condition occurs three consecutive times, the SC is generated. For the LCT If the upper or lower limit is not detected within 8 seconds when the tray lift motor is turned on to lift up or lower the tray
Causes: • Defective tray lift motor or connector disconnection • Defective lift sensor or connector disconnection
Remedy: 1. Check the cable connections. 2. Check and/or replace the defective component.
Description: Tray 4 error (3 Tray Paper Feed Unit) This SC is generated if the following condition occurs 3 consecutive times. For the two-tray paper feed unit • When the tray lowers, the tray lift sensor does not go off within 1.5 sec. For the LCT • If the upper limit does not go off for 1.5 seconds even the tray lift motor turns on to lower the tray after the upper limit has been detected at power on.
Causes: • Defective tray lift motor or connector disconnection • Defective lift sensor or connector disconnection
Remedy: 1. Check the cable connections. 2. Check and/or replace the defective component.
Description: Junction gate 1 motor error The junction gate 1 HP sensor does not detect the home position of junction gate 1 for 0.15 seconds when the machine starts to detect its home position. The junction gate 1 HP sensor does not turn off for 0.1 seconds after the machine has detected its home position.
Causes: • Disconnected or defective junction gate 1 motor • Disconnected or defective junction gate 1 HP sensor • Mechanical problem (such as paper jam etc.) • Shorted 24 V fuse on the PSU • Defective IOB
Remedy: 1. Remove any objects that obstruct junction gate 1. 2. Replace the junction gate 1 HP sensor. 3. Replace the junction gate 1 motor. 4. Replace the 24 V fuse on the PSU. 5. Replace the IOB.
Description: Ventilation fan (at the left side of the machine) motor-front/rear error The IOB does not receive the lock signal for 2 seconds after turning on the ventilation fan motor-front/rear.
Causes: • Defective ventilation fan motor-front or rear
Remedy: Replace the ventilation fan (at the left side of the machine) motor-front or rear.