Description: Ferrite core rotation error The ferrite roller HP sensor does not detect the ferrite roller home position for 4 seconds after the fusing/paper exit motor has turned on.
Causes: • Deformed actuator for the ferrite roller HP sensor • Defective ferrite roller HP sensor • Defective ferrite roller motor • Shorted +24V fuse on the PSU • Defective IOB
Remedy: 1. Replace the heating roller. 2. Replace the ferrite roller HP sensor. 3. Replace the ferrite roller motor. 4. Replace the +24V fuse on the PSU. 5. Replace the IOB.
Description: Heating roller warm-up error 2 • The heating roller temperature does not reach the ready temperature for 90 seconds after the heating lamp on. • The heating roller temperature does not reach 80°C for 13 seconds after the IH inverter on.
Causes: • Defective thermistor • Defective IH inverter
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the IH inverter
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Description: Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Remedy: Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.