Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
Code: 544
Description: Heating roller fusing lamp overheat 1 (hardware error) During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
Code: 547
Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU
Code: 548
Description: Fusing unit rotation error The heating roller rotation sensor does not detect change in the actuator for 0.5 seconds after the fusing/paper exit motor has turned on.
Causes: • Defective fusing/paper exit motor • Deformed actuator for the heating roller rotation sensor • Defective heating roller rotation sensor • Broken connection between IH inverter and IOB • Incorrectly set fusing unit
Remedy: 1. Check if the fusing unit is correctly set. 2. Check or replace the actuator for heating roller rotation sensor. 3. Replace the heating roller rotation sensor. 4. Replace the IH inverter. 5. Check the connection between IH inverter and IOB.
Code: 551
Description: Heating roller thermistor error The temperature at the end of the heating roller measured by the heating roller thermistor does not reach 0°C for 7 seconds.
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.
Code: 552
Description: Heating roller warm-up error 2 • The heating roller temperature does not reach 80°C for 20 seconds after the IH inverter turned on. • The temperature at the end of the heating roller does not reach the ready temperature for 89 seconds after the IH inverter turned on.
Causes: • Defective heating roller thermistor • Defective IH inverter
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the IH inverter.
Code: 553
Description: Heating roller overheat (software error) The detected heating roller temperature stays at 245°C or more for 1 second.