Các lỗi thường gặp

Code :
  • Code: SC409
  • Description: ID Sensor Pattern Minimum Coverage Error 4: Y
    The machine detected 10 times that the amount of toner applied to create the yellow ID sensor pattern on the drum between sheets (SP3101-4 ID Pattern Display - Applied Y) was less than the minimum threshold setting (0.2 mg/cm2). Also, the total time for the operation of the sub hopper clutch (SP3251-4 Tnr Supply Time - Sub Hopper CL: Y) was less than or equal to the threshold of 65K ms.
  • Causes: • Toner shield glass dirty • Development unit defective • Image transfer unit defective
  • Code: SC410
  • Description: ID sensor error: Development K
    Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
  • Code: SC411
  • Description: ID sensor error: Development M
    Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
  • Code: SC412
  • Description: ID sensor error: Development C
    Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
  • Code: SC413
  • Description: ID sensor error: Development Y
    Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
  • Code: SC414
  • Description: ID sensor error: Development start voltage K
    The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
  • Code: SC415
  • Description: ID sensor error: Development start voltage M
    The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
  • Code: SC416
  • Description: ID sensor error: Development start voltage C
    The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)
  • Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective