Description: TD sensor (Vt high) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC361
Description: TD sensor (Vt high) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC362
Description: TD sensor (Vt high) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC363
Description: TD sensor (Vt high) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC364
Description: TD sensor (Vt low) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC365
Description: TD sensor (Vt low) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC366
Description: TD sensor (Vt low) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Code: SC367
Description: TD sensor (Vt low) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.