Các lỗi thường gặp

Code :
  • Code: SC543
  • Description: Heating roller thermistor (center) error 2
    The thermistor at the center of the heating roller detected an abnormally high temperature (over 250°C)
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC544
  • Description: Heating roller thermistor (center) error 3
    The thermistor detected a temperature over 260°C..
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC545
  • Description: Lamp remains on
    After hot roller reaches warm-up temperature, the center fusing lamps in the heating roller remained on at full capacity after reaching the warm-up temperature while the hot roller was not rotating.
  • Causes: • Do SP5810 to cancel the SC fusing code. • Heating roller thermistor damaged, or out of position • Fusing lamp disconnected, broken
  • Code: SC546
  • Description: Heating roller thermistor error (side)
    The temperature measured by the heating roller thermistor does not reach 0°C after 50 sec. and remains over this temperature for 10 readings.
  • Causes: • Loose connection of the heating roller thermistor • Defective heating roller thermistor
  • Code: SC547
  • Description: Zero cross error
    When the main switch is turned on, the machine checks how many zero-cross signals are generated within 500 ms. This SC code is issued if the number of zero-cross signals detected is not within specification. Note: Zero cross signals, generated from an ac power supply, are used to generate a trigger pulses to control the applied power accurately.
  • Causes: • Do SP5810 to cancel the SC fusing code. • Electrical noise on the power supply line • Fusing relay damaged, replace the AC drive board.
  • Code: SC549
  • Description: Heating roller thermistor (center): software error
    The thermistor detected a temperature over 250°C 10 times within 1 sec.
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC550
  • Description: Heating roller thermistor 3 (side): hardware error
    The thermistor detected a temperature over 260°C.
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC551
  • Description: Pressure roller thermistor error 1
    The temperature measured by the pressure roller thermistor did not reach 0°C after 10 attempts.
  • Causes: • Do SP5810 to cancel the SC fusing code. • Loose connection of the pressure roller thermistor • Thermistor positioned incorrectly • Defective pressure roller thermistor