Description: Laser Synchronization Detector Error: Y Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for yellow, leading edge for any LD other than LD0.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: Laser Synchronization Detector Error: M Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 magenta, leading edge.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: Laser Synchronization Detector Error: M Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for magenta, leading edge for any LD other than LD0.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: Laser Synchronization Detector Error: C Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 cyan, leading edge.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: Laser Synchronization Detector Error: C Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for cyan, leading edgefor any LD other than LD0.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: FGATE error: Feedback remains HIGH for K write
After the start of timing to create the black image, the PFGATE register of the GAVD did not assert
Causes: • Harness between the VBCU and LDB unit disconnected, loose, or defective. • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
Description: FGATE error: Feedback remains LOW for K write
After the start of timing to create the black image, the PFGATE register of the GAVD did not assert.
Causes: • Harness between the VBCU and LDB unit disconnected, loose, or defective. • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
Description: FGATE error: Feedback remains HIGH for Y write
After the start of timing to create the yellow image, the PFGATE register of the GAVD did not assert.
Causes: • Harness between the VBCU and LDB unit disconnected, loose, or defective. • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.